RED-D-ARC
IM994-A
September, 2010
RED-D-ARC
LN-25™ PRO EXTREME (CE)
IM994-A
September, 2010
Red-D-Arc Spec-Built Welding Equipment
This
RED-D-ARC
welder is built to
RED-D-ARC Extreme Duty
design specifications by Lincoln Electric.
Safety Depends on You
This welder is designed and built with safety in mind.
However, your overall safety can be increased by proper installation
... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
For use with machines having Code Numbers: 11533, 11719
North America’s Largest Fleet of Welding Equipment
1-800-245-3660
OPERATOR’S MANUAL
Vue de la page 0
1 2 3 4 5 6 ... 44 45

Résumé du contenu

Page 1 - RED-D-ARC

RED-D-ARCIM994-ASeptember, 2010RED-D-ARC LN-25™ PRO EXTREME (CE)IM994-ASeptember, 2010Red-D-Arc Spec-Built Welding EquipmentThisRED-D-ARCwelder is bui

Page 2 - MAGNETIC FIELDS

A-1INSTALLATION A-1RED-D-ARC LN-25™ PRO DUAL POWER (CE) TEMPERATURE RANGEOPERATION: -40°F to 104°F (-40°C to 40°C)STORAGE: -40°F to 185°F (-40°C to

Page 3 - ARC RAYS can burn

WELD CABLE SIZETable A.1 located below are copper cable sizes rec-ommended for different currents and duty cycles.Lengths stipulated are the distance

Page 4

A-3INSTALLATION RED-D-ARC LN-25™ PRO DUAL POWER (CE) A-3SHIELDING GAS CONNECTIONCYLINDER may explode ifdamaged.• Keep cylinder upright andchained to

Page 5 - REDRESSEUR

A-4INSTALLATION RED-D-ARC LN-25™ PRO DUAL POWER (CE) A-4WIRE DRIVE CONFIGURATION(See Figure A.2)CHANGING THE GUN RECEIVERBUSHINGELECTRIC SHOCK can k

Page 6

THUMBSCREWGUNA-5INSTALLATION RED-D-ARC LN-25™ PRO DUAL POWER (CE) A-5PRESSURE ARM ADJUSTMENTELECTRIC SHOCK can kill.• Turn the input power OFF at t

Page 7

A-6INSTALLATION RED-D-ARC LN-25™ PRO DUAL POWER (CE) A-6ACROSS THE ARC SET-UPSCC Power Sources with Output Terminals AlwaysHot (See Figure A.5)If th

Page 8 - Thank You

A-7INSTALLATION RED-D-ARC LN-25™ PRO DUAL POWER (CE) A-7CV Power Sources with Stud Connectors and noRemote/Local Switch. (See Figure A.7)Place CV/CC

Page 9 - TABLE OF CONTENTS

A-8INSTALLATION RED-D-ARC LN-25™ PRO DUAL POWER (CE) A-8CV Power Source with Twist-Mate Connectors andno Remote/Local Switch. (See Figure A.9)Place

Page 10 - INSTALLATION

B-1OPERATIONRED-D-ARC LN-25™ PRO DUAL POWER (CE) B-1• ELECTRIC SHOCK CAN KILL.Unless using COLD FEED fea-ture, when feeding with gun trig-ger, the ele

Page 11

B-2OPERATIONB-2RED-D-ARC LN-25™ PRO DUAL POWER (CE)DEFINITION OF WELDING TERMSWFS• Wire Feed SpeedCC• Constant CurrentCV• Constant VoltageGMAW• Gas Me

Page 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Page 13

B-3OPERATIONB-3RED-D-ARC LN-25™ PRO DUAL POWER (CE)Wire Feed Speed, CV OperationWhen Across the Arc models are operated with CVpower sources, the wire

Page 14

B-4OPERATIONB-4RED-D-ARC LN-25™ PRO DUAL POWER (CE)CASE FRONT CONTROLSFigure B.1ITEM DESCRIPTION1 Wire Feed Speed/Amperage Display2 Wire Feed Sp

Page 15

B-5OPERATIONB-5POWER-UP SEQUENCEAll of the LEDʼs will briefly illuminate during power-up.If the gun trigger is activated during power up, thefeeder wi

Page 16

B-6OPERATIONB-6RED-D-ARC LN-25™ PRO DUAL POWER (CE)WFS CALIBRATION WITH DIGITALMETERS (K2614-1, K2614-2, K2613-4)To calibrate the wire feed speed, bef

Page 17

B-7OPERATIONB-7INTERNAL CONTROLSRED-D-ARC LN-25™ PRO DUAL POWER (CE)1 2 Step Trigger Interlock Switch2 CV / CC Switch3 Pressure Adjustment Arm4 Op

Page 18 - OPERATION

B-8OPERATIONB-8INTERNAL CONTROLS DESCRIPTION(See Figure B.2)2 Step - Trigger Interlock SwitchThe 2 Step - Trigger Interlockswitch changes the function

Page 19

B-9OPERATIONB-9RED-D-ARC LN-25™ PRO DUAL POWER (CE)CONSTANT CURRENT WIRE WELDING (See Figure B.3)Most semiautomatic welding processes perform betterus

Page 20

B-10OPERATIONB-10REAR CONTROLS:RED-D-ARC LN-25™ PRO DUAL POWER (CE)1 Gas Purge Pushbutton2 Flow Meter Ball4 Shielding Gas Inlet3 Flow Meter Valve6

Page 21

B-11OPERATIONB-111. GAS PURGE PUSHBUTTON(See Figure B.4)The gas solenoid valve will energize but neither thepower source output nor the drive motor wi

Page 22 - LN-25 PRO

C-1ACCESSORIESC-1RED-D-ARC LN-25™ PRO DUAL POWER (CE)WIRE TYPESteel Wires:Cored Wires:Aluminum Wires:ELECTRODE SIZE.023-.030 (0.6-0.8mm).035 (0.9mm).0

Page 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Page 24

C-2ACCESSORIESC-2RED-D-ARC LN-25™ PRO DUAL POWER (CE)K1796-xxK2593-xxK1803-1K1840-xxK1842-xxAWG 1/0 Co-Axial Power CableAWG #1 Coaxial Power Cable Wor

Page 25

C-3ACCESSORIESC-3RED-D-ARC LN-25™ PRO DUAL POWER (CE)K1797-xxK2335-1K484K1520-1(requires DigitalMeter/remotecontrol kit)K1798(requiresremote controlki

Page 26

C-4ACCESSORIESC-4RED-D-ARC LN-25™ PRO DUAL POWER (CE)K910-1K910-2K1500-1K1500-2K1500-3Ground ClampGround ClampGun Receiver Bushing (for gunswith K466-

Page 27

C-5ACCESSORIESC-5RED-D-ARC LN-25™ PRO DUAL POWER (CE)K1500-4K1500-5K489-7K435K468K590-6K586-1Gun Receiver Bushing (for gunwith K466-3 Lincoln gun conn

Page 28

C-6ACCESSORIESC-6RED-D-ARC LN-25™ PRO DUAL POWER (CE)INSTALLATION OF THE K590-6 WATERCOOLING KITELECTRIC SHOCK can kill.• Turn the input power OFF at

Page 29 - ACCESSORIES

ELECTRIC SHOCK can kill.• Turn the input power OFF at thewelding power source beforeinstallation or changing driverolls and/or guides.•Do not touch el

Page 30

D-2MAINTENANCED-2Wire Feed Speed Validation(See Figure D.1)Calibration of the Red-D-Arc LN-25™ PRO DUALPOWERmay be required when the p.c. board, wire

Page 31

E-1TROUBLESHOOTINGE-1RED-D-ARC LN-25™ PRO DUAL POWER (CE)HOW TO USE TROUBLESHOOTING GUIDEWARNINGELECTRIC SHOCK can kill.• Turn the input power OFF at

Page 32

E-2TROUBLESHOOTINGE-2RED-D-ARC LN-25™ PRO DUAL POWER (CE)Observe all Safety Guidelines detailed throughout this manualPROBLEMS(SYMPTOMS)POSSIBLE CAUSE

Page 33

E-3TROUBLESHOOTINGE-3RED-D-ARC LN-25™ PRO DUAL POWER (CE)Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not und

Page 34

iiiSAFETYiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.

Page 35 - MAINTENANCE

E-4TROUBLESHOOTINGE-4RED-D-ARC LN-25™ PRO DUAL POWER (CE)Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not und

Page 36

F-1DIAGRAMSF-1RED-D-ARC LN-25™ PRO DUAL POWER (CE)NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this

Page 37 - TROUBLESHOOTING

F-2DIMENSION PRINTF-2RED-D-ARC LN-25™ PRO DUAL POWER (CE)17.198.6516” CIRCLE12” x 18” ELLIPSE 23.1714.8117.198.6516” CIRCLE12” x 18” ELLIPSE 23.1714.8

Page 38

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Page 39

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Page 40

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB 

Page 41 - ENHANCED DIAGRAM

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra

Page 42 - DIMENSION PRINT

vSAFETYvRED-D-ARC LN-25™ PRO DUAL POWER (CE)Electromagnetic Compatibility (EMC)ConformanceProducts displaying the CE mark are in conformity with Europ

Page 43

viSAFETYviRED-D-ARC LN-25™ PRO DUAL POWER (CE)Electromagnetic Compatibility (EMC)The size of the surrounding area to be considered will depend on the

Page 44

viiviiThank Youfor selecting one of our QUALITY products. We want you to takepride in operating this product ••• as much pride as we have inbringing t

Page 45

viiiviii TABLE OF CONTENTSPage––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––Installation.......

Commentaires sur ces manuels