9.Control of the ArcPower 360 via RS-232
9.1Wiring an RS-232 serial port
9-pin D connector (male)
Front view of the socket:
RS-232 cable:
9-pin D connector- female 9-pin D connector - female
ArcPower driver PC
Pin 1: Pin 1:
Pin 2: Received Data Pin 2: Received Data
Pin 3: Transmited data Pin 3: Transmited data
Pin 4: Pin 4:
Pin 5: Signal ground Pin 5: Signal ground
Pin 6: Pin 6:
Pin 7: Pin 7:
Pin 8: Pin 8:
Pin 9: Pin 9:
The maximum cable length according to the standard is 15 metres or the cable length equals to a capacitance
of 2500 pF.
9.2 Zone number
The number of the zone distinguishes individual zones of the ArcPower 360 which is controled via RS-232
interface.
The sequence of the zones is following:
9.3 Setting a serial port of PC
The serial port of your personal computer hould be congured as follows:
9600 Baud,8 Data Bits,Non Parity,One Stop Bit,No Flow Control Required.
9.4 Zone commands
The ArcPower 360 uses the 3 types of the zone commands which can be used in a suitable software running
on PC.
All zone commands stated below have to be send to the ArcPower 360 in ASCII codes.
Pin 1: Not connected
Pin 2: Received Data
Pin 3: Transmitted Data
Pin 4:
Pin 5: Signal Ground
Pin 6:
Pin 7:
Pin 8:
Pin 9: Not connected